INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODELS EZ24-3, EZ24-5
MANUAL 1195731 rev0 (11/22/2011) 18 HEAVY DUTY STEAM
7.0 PREVENTIVE MAINTENANCE (Continued)
5. Set the power switch to “TIMED COOKING” and set the timer to 30 minutes.
6. At the end of the 30 minute cook cycle, turn power switch “OFF” and drain the contents of
the cavity.
7. Thoroughly flush the cavity with clean water and dry with a soft cloth. LEAVE
COMPARTMENT DOOR OPEN WHEN NOT IN USE. The steamer is now ready for use.
Turn off for overnight shutdown.