INSTALLATION STRATOSTEAM EZ COUNTERTOP STEAMER
PAGE 16 OF 56 OWNERS MANUAL 1189953 (10/08)
For 3-wire 3-phase installations, connect wires L1, L2, and L3 to the three terminals on the upper end of the contactor.
For 2-wire 1-phase installations, connect wires L1 and L2 to the two outer terminals on the upper end of the contactor.
Make the electrical ground connection to the ground lug located at the top right-hand corner of the contactor bracket.
Figure 7
Electrical Connection
L1 L2 L3
Connections
to Contactor for
3-Phase Models
Top of
Steamer
Contactor
Cable Support Bracke
t
L1 L2
Connections
to Contactor for
1-Phase Models
Top of
Steamer
Time Delay Rela
y
Pressure Switch
Water Fill Solenoid
Water Level Switch